Customization: | Available |
---|---|
Warranty: | 12 Monthes Excellent After Service |
Usage: | Universal Textile Testing, Textile Fabric Testing |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Impact Protection Tester :For gloves that are designed, constructed and claimed to provide specific impact attenuation, the materials shall not crack when a 2.5kg load with an impact energy of 5J drops on the tested material- peak transmitted shall also be <7 KN.
It is used for protective clothing impact test.
Adopt high precision piezoelectric ceramic force sensor, high resolution, fast reaction, good repeability, the machine controlled by computer, all test process is through computer controlled, automatic record impact force, automatic calculate average impact force, testing report also be available.
Test Standard:
For Protective Clothing: EN 1621-1, EN 1621-2 For Protective Gloves: EN 13594, EN 388
Technical Parameter:
For Protective Clothing |
|
Force measurement |
0-60000N |
Frequency response range |
5-1000Hz |
Lift device |
Motorized system, have upper and lower limit |
Dimension |
650mm×770mm×2200mm |
Power Supply |
AC 220V+/-10%, 50Hz |
EN 1621-1 |
|
Mass of striker |
5000+/-10g |
Flat Striking Surface |
40mmx80mm |
Round Edges of Striker |
5+/-0.5mm Radius |
Impact energy |
50J+/-2J |
Anvil Radius |
50mm |
Total Height of Anvil |
180+/-20mm |
EN 1621-2 |
|
Bar Impactor Length |
160+/-2mm |
Bar Impactor Width |
50+/-1mm |
Bar Impactor Cylindrical Face Radius |
12.5+/-0.1mm |
Mass of impactor and guided mass |
5000g+/-50g |
Impact Energy |
50+/-1.5J |
Anvil Height |
190+/-20mm |
For Protective Gloves |
|
Mass of striker |
2.5kg |
Impact energy |
5J |
Flat face of striker |
80mm |
Force measurement |
Force measurement |
Lift device |
Motorized system, have upper and lower limit |
Dimension |
650mm×770mm×2200mm |
Power Supply |
AC 220V+/-10%, 50Hz |
1. How About Machines Calibration?